Description
Acid resistant high temperature coating with extended working time
M-CHEM 401 is an acid resistant high temperature coating: a two-pack, 100% solids epoxy novolac for steel and concrete in harsh chemical service. It is the extended working time version of M-CHEM 400, with a 45-minute pot life at 20°C.
Unlike M-CHEM 400, it does not need a plural-feed rig. Apply two coats of 500 µm by brush, medium-pile roller or standard airless spray with heated lines, which suits large or complex areas.
It resists strong acids and alkalis in immersion up to 60°C, including 98% sulphuric acid and 36% hydrochloric acid, with dry heat resistance up to 200°C depending on load.
Where to use this acid resistant coating
- Tank linings and process vessels
- Sumps and chemical containment areas
- Chemical drains and channels
- Internal pipe surfaces
- Large or complex areas that need longer working time
Coverage calculator
How much M-CHEM 401 do I need?
Enter your area and we’ll work out the litres and the most economical mix of 4 L and 16 L kits.
Theoretical coverage for M-CHEM 401 (100% solids). Actual use depends on surface profile, application method and site conditions. For primed concrete, also allow for the primer.
Application guide
How to apply this acid resistant high temperature coating, in short. Full instructions are in the product data sheet.
Surface preparation: steel
- Remove all oil and grease with MEK or a similar solvent cleaner.
- Abrasive blast to ISO 8501-1 Sa 2½ (SSPC-SP10 / NACE 2) with an angular abrasive and a minimum 75 µm profile.
- Degrease again after blasting and coat before any flash rusting appears.
- Where salts are present, pressure wash with clean water and test for residual salts before coating.
Surface preparation: concrete
- New concrete must have cured for at least 21 days. Remove all laitance and check moisture is 8% or below.
- Lightly abrasive blast or scarify without exposing the aggregate, then remove all dust and debris.
- Prime with M-PRIME 100 at 150 µm WFT and leave at least 3 hours at 20°C before overcoating (36 hours maximum).
Conditions and mixing
- Store the base at 15–25°C before mixing. Apply only when air and surface temperature is above 10°C and the surface is at least 3°C above dew point.
- Pour all of the activator into the base and mix with an electric paddle mixer until uniform and streak-free. Mix full units only.
- Use within 45 minutes at 20°C. Decanting into a kettle or tray extends usable life.
Brush and roller
- Stripe coat edges, joints and corners with a 50 mm synthetic brush, about 100 mm wide at 500 µm WFT.
- Once the stripe can be overcoated, apply the first coat at 500 µm WFT with a brush or medium-pile roller.
- Allow about 8 hours at 20°C, then apply the second coat at 500 µm WFT.
Airless spray
- Use a 60:1 airless pump with a hot water pump to heat the lines to 25–35°C. Keep lines to 8 m maximum and circulate briefly to reach temperature.
- Spray at 3,500 psi with a 19–23 thou tip, after brushing the stripe coat.
- Apply two coats at 500 µm WFT, about 8 hours apart at 20°C. Post-cure for 6 hours at 60°C for full mechanical properties.
Technical data
Typical values for M-CHEM 401 acid resistant high temperature coating. Usable life is timed from mixing; overcoat and cure times from application.
| Property | Value |
|---|---|
| Mix ratio | 3.25 : 1 by volume · 4.35 : 1 by weight |
| Mixed density | 1.33 |
| Solids | 100% |
| Sag resistance | Nil at 500 µm |
| Coverage per coat at 500 µm | 2 m²/L · 32 m² per 16 L |
| Hardness (ASTM D2240) | Shore D 86 |
| Compressive strength (ASTM D695) | 901 kg/cm² |
| Flexural strength (ASTM D790) | 810 kg/cm² |
| Tensile shear adhesion (ASTM D1002) | 201 kg/cm² |
| Heat distortion (ASTM D648) | 60°C ambient · 98°C at 100°C cure · 112°C at 150°C cure |
| Abrasion (Taber CS17, 1 kg) | 138 mg per 1000 cycles |
| Heat resistance | 60°C immersed · 200°C dry |
| Shelf life | 5 years unopened, 15–30°C |
| Temp. | Usable life | Overcoat | Water immersion |
|---|---|---|---|
| 10°C | 90 min | 16–24 h | 8 days |
| 20°C | 45 min | 8–24 h | 4 days |
| 30°C | 22 min | 4–12 h | 2 days |
| 40°C | 11 min | 2–6 h | 1 day |
Post-cure for 6 hours at 60°C for full mechanical properties. Contact our technical team for chemical immersion times for your duty.
Chemical resistance
Published resistance for this acid resistant high temperature coating after full cure. Continuous immersion is limited to 60°C.
| Chemical | Concentration | Max °C | Chemical | Concentration | Max °C |
|---|---|---|---|---|---|
| Sulphuric acid | 98% | 75 | Hydrocarbons with steam | – | 75 |
| Hydrochloric acid | 36% | 60 | Benzene | 100% | 60 |
| Phosphoric acid | 75% | 75 | Toluene | 100% | 60 |
| Hydrobromic acid | 40% | 50 | Xylene | 100% | 60 |
| Chromic acid | 10% | 75 | Ethanol | 100% | 60 |
| Nitric acid | 10% | 50 | Butanol | 100% | 50 |
| Acetic acid | 10% | 50 | Steam out | – | 200 |
| Ammonium hydroxide | 30% | 75 |
Figures above 60°C are the manufacturer’s published limits for each medium. For duties above 60°C, or chemicals not listed, contact our technical team before specifying. For continuous immersion up to 110°C, see M-CHEM 400.
Which Maxkote chemical resistant coating do I need?
M-CHEM 401 gives you novolac acid resistance with a long working time and simple application. For hotter immersion up to 110°C, and a plural-feed rig on site, choose M-CHEM 400.
| Product | Type | Best for | Strongest acid tested | Max. immersion | Dry heat |
|---|---|---|---|---|---|
| M-CHEM 100 | Surface tolerant epoxy | Corrosion and low-concentration chemicals, power-tool or hydro-blasted steel, cold sites. Applied by brush or roller. | Sulphuric acid 20% at 40°C | 60°C | 200°C |
| M-CHEM 300 | Epoxy novolac | Concentrated acids: bunds, sumps, tank linings. Applied by brush, roller or airless spray. | Sulphuric acid 98% at 40°C | 60°C | 200°C |
| M-CHEM 400 | High temperature epoxy novolac | Hot process tanks and vessels, one coat at 1000 µm. Heated plural-feed spray only. | Sulphuric acid 98% at 75°C | 110°C | 170°C |
| M-CHEM 401 (this product) | Epoxy novolac, extended working time | Large or complex linings needing a long pot life. Applied by brush, roller or airless spray. | Sulphuric acid 98% | 60°C | 200°C |
Need a trowelled floor rather than a coating? See M-CRETE 300 acid resistant epoxy novolac screed and our guide to choosing the right acid resistant flooring.
Downloads
Data sheets for M-CHEM 401 acid resistant high temperature coating, for specifiers, O&M files and tender packs. Technical data revised November 2026.
Frequently asked questions
Quick answers for contractors and specifiers.





Reviews
There are no reviews yet.