Previous
M-CHEM 101 - Chemical Resistant Epoxy Coating - Extended Cure

M-CHEM 101 – Chemical Resistant Epoxy Coating – Extended Cure

Next

M-CHEM 501 – Erosion & Acid Resistant Epoxy Coating

Price range: £285.00 through £960.00 Excl VAT
chemical bund lining
acid resistant epoxy coating for high temperature applications

M-CHEM 401 - Acid Resistant High Temperature Coating - Extended Cure

Price range: £247.50 through £821.00 Excl VAT

M-CHEM 401 – Acid Resistant High Temperature Coating – Extended Cure

Price range: £247.50 through £821.00 Excl VAT

An extended working time epoxy novolac lining for strong acids, applied by brush, roller or standard airless spray. Ideal for large or complex jobs.
100% solids45 min pot life at 20°C2 × 500 µm coats98% sulphuric acid
4 L and 16 L kits · dark grey or red
  • UK delivery by specialist courier (not Royal Mail), priced by weight at checkout
  • Dispatched on a 3–5 working day service, tracking emailed, signed for on delivery
  • Highlands, islands and Northern Ireland: call 0800 654 6199 for a delivery quote
  • Returns: some products can’t be returned for health reasons. Delivery and returns terms
Not sure it suits your chemicals? Talk to our technical team before you order.

0800 654 6199

Description

45 min
usable life at 20°C, for large or complex jobs
98%
sulphuric acid resistance
60°C
maximum immersed service temperature
200°C
dry heat resistance, depending on load
5,000 h
salt-spray resistance (ASTM B117)

Acid resistant high temperature coating with extended working time

M-CHEM 401 is an acid resistant high temperature coating: a two-pack, 100% solids epoxy novolac for steel and concrete in harsh chemical service. It is the extended working time version of M-CHEM 400, with a 45-minute pot life at 20°C.

Unlike M-CHEM 400, it does not need a plural-feed rig. Apply two coats of 500 µm by brush, medium-pile roller or standard airless spray with heated lines, which suits large or complex areas.

It resists strong acids and alkalis in immersion up to 60°C, including 98% sulphuric acid and 36% hydrochloric acid, with dry heat resistance up to 200°C depending on load.

Where to use this acid resistant coating

  • Tank linings and process vessels
  • Sumps and chemical containment areas
  • Chemical drains and channels
  • Internal pipe surfaces
  • Large or complex areas that need longer working time
CONCRETE SYSTEM

Coating concrete? Prime it first

Concrete must be at least 21 days old with a moisture content of 8% or below. Prime with M-PRIME 100 low-viscosity primer at 150 µm and leave at least 3 hours at 20°C before applying M-CHEM 401.

System build-up
Concrete substrate
M-PRIME 100150 µm
M-CHEM 401 · coat 1500 µm
M-CHEM 401 · coat 2500 µm
Total system: 1150 µm

Coverage calculator

How much M-CHEM 401 do I need?

Enter your area and we’ll work out the litres and the most economical mix of 4 L and 16 L kits.

Material needed
–
Most economical kits
Enter an area to see the kits you need
Estimated cost
–

Theoretical coverage for M-CHEM 401 (100% solids). Actual use depends on surface profile, application method and site conditions. For primed concrete, also allow for the primer.

Application guide

How to apply this acid resistant high temperature coating, in short. Full instructions are in the product data sheet.

Surface preparation: steel
  1. Remove all oil and grease with MEK or a similar solvent cleaner.
  2. Abrasive blast to ISO 8501-1 Sa 2½ (SSPC-SP10 / NACE 2) with an angular abrasive and a minimum 75 µm profile.
  3. Degrease again after blasting and coat before any flash rusting appears.
  4. Where salts are present, pressure wash with clean water and test for residual salts before coating.
Surface preparation: concrete
  1. New concrete must have cured for at least 21 days. Remove all laitance and check moisture is 8% or below.
  2. Lightly abrasive blast or scarify without exposing the aggregate, then remove all dust and debris.
  3. Prime with M-PRIME 100 at 150 µm WFT and leave at least 3 hours at 20°C before overcoating (36 hours maximum).
Conditions and mixing
  • Store the base at 15–25°C before mixing. Apply only when air and surface temperature is above 10°C and the surface is at least 3°C above dew point.
  • Pour all of the activator into the base and mix with an electric paddle mixer until uniform and streak-free. Mix full units only.
  • Use within 45 minutes at 20°C. Decanting into a kettle or tray extends usable life.
Brush and roller
  1. Stripe coat edges, joints and corners with a 50 mm synthetic brush, about 100 mm wide at 500 µm WFT.
  2. Once the stripe can be overcoated, apply the first coat at 500 µm WFT with a brush or medium-pile roller.
  3. Allow about 8 hours at 20°C, then apply the second coat at 500 µm WFT.
Airless spray
  • Use a 60:1 airless pump with a hot water pump to heat the lines to 25–35°C. Keep lines to 8 m maximum and circulate briefly to reach temperature.
  • Spray at 3,500 psi with a 19–23 thou tip, after brushing the stripe coat.
  • Apply two coats at 500 µm WFT, about 8 hours apart at 20°C. Post-cure for 6 hours at 60°C for full mechanical properties.

Technical data

Typical values for M-CHEM 401 acid resistant high temperature coating. Usable life is timed from mixing; overcoat and cure times from application.

Property Value
Mix ratio 3.25 : 1 by volume · 4.35 : 1 by weight
Mixed density 1.33
Solids 100%
Sag resistance Nil at 500 µm
Coverage per coat at 500 µm 2 m²/L · 32 m² per 16 L
Hardness (ASTM D2240) Shore D 86
Compressive strength (ASTM D695) 901 kg/cm²
Flexural strength (ASTM D790) 810 kg/cm²
Tensile shear adhesion (ASTM D1002) 201 kg/cm²
Heat distortion (ASTM D648) 60°C ambient · 98°C at 100°C cure · 112°C at 150°C cure
Abrasion (Taber CS17, 1 kg) 138 mg per 1000 cycles
Heat resistance 60°C immersed · 200°C dry
Shelf life 5 years unopened, 15–30°C
Temp. Usable life Overcoat Water immersion
10°C 90 min 16–24 h 8 days
20°C 45 min 8–24 h 4 days
30°C 22 min 4–12 h 2 days
40°C 11 min 2–6 h 1 day

Post-cure for 6 hours at 60°C for full mechanical properties. Contact our technical team for chemical immersion times for your duty.

Chemical resistance

Published resistance for this acid resistant high temperature coating after full cure. Continuous immersion is limited to 60°C.

Chemical Concentration Max °C Chemical Concentration Max °C
Sulphuric acid 98% 75 Hydrocarbons with steam – 75
Hydrochloric acid 36% 60 Benzene 100% 60
Phosphoric acid 75% 75 Toluene 100% 60
Hydrobromic acid 40% 50 Xylene 100% 60
Chromic acid 10% 75 Ethanol 100% 60
Nitric acid 10% 50 Butanol 100% 50
Acetic acid 10% 50 Steam out – 200
Ammonium hydroxide 30% 75

Figures above 60°C are the manufacturer’s published limits for each medium. For duties above 60°C, or chemicals not listed, contact our technical team before specifying. For continuous immersion up to 110°C, see M-CHEM 400.

Not sure it suits your chemicals? Talk to our technical team before you order.

0800 654 6199

Which Maxkote chemical resistant coating do I need?

M-CHEM 401 gives you novolac acid resistance with a long working time and simple application. For hotter immersion up to 110°C, and a plural-feed rig on site, choose M-CHEM 400.

Product Type Best for Strongest acid tested Max. immersion Dry heat
M-CHEM 100 Surface tolerant epoxy Corrosion and low-concentration chemicals, power-tool or hydro-blasted steel, cold sites. Applied by brush or roller. Sulphuric acid 20% at 40°C 60°C 200°C
M-CHEM 300 Epoxy novolac Concentrated acids: bunds, sumps, tank linings. Applied by brush, roller or airless spray. Sulphuric acid 98% at 40°C 60°C 200°C
M-CHEM 400 High temperature epoxy novolac Hot process tanks and vessels, one coat at 1000 µm. Heated plural-feed spray only. Sulphuric acid 98% at 75°C 110°C 170°C
M-CHEM 401 (this product) Epoxy novolac, extended working time Large or complex linings needing a long pot life. Applied by brush, roller or airless spray. Sulphuric acid 98% 60°C 200°C

Need a trowelled floor rather than a coating? See M-CRETE 300 acid resistant epoxy novolac screed and our guide to choosing the right acid resistant flooring.

Downloads

Data sheets for M-CHEM 401 acid resistant high temperature coating, for specifiers, O&M files and tender packs. Technical data revised November 2026.

Frequently asked questions

Quick answers for contractors and specifiers.

What is the difference between M-CHEM 400 and M-CHEM 401?
M-CHEM 401 has a 45-minute pot life at 20°C and goes on in two 500 µm coats by brush, roller or standard airless spray. M-CHEM 400 is a one-coat, 1000 µm system for heated plural-feed spray, rated for immersion up to 110°C rather than 60°C.
How much M-CHEM 401 do I need?
Each 500 µm coat uses 0.5 L per m², so the two-coat system needs 1 L per m². A 16 L kit covers 32 m² per coat and a 4 L kit 8 m². Allow extra for surface profile and losses.
Can M-CHEM 401 be sprayed?
Yes, with a 60:1 airless pump and lines heated to 25–35°C, no longer than 8 m. Spray at 3,500 psi with a 19–23 thou tip, after brushing the stripe coat.
What temperatures can it handle?
Continuous immersion up to 60°C and dry heat up to 200°C, depending on load. It resists 98% sulphuric acid and 36% hydrochloric acid.
Does it need a post-cure?
For full mechanical properties, post-cure for 6 hours at 60°C. At 20°C allow 4 days before water immersion, and talk to our technical team about chemical immersion times.

Additional information

Weight N/A
Unit Size

16ltr, 4ltr

Colour

Dark Grey, Red

Mixing Ratio

3.25:1 By Volume, 4.35:1 By Weight

Brand

Maxkote

Manufacturer

Maxkote

Reviews

There are no reviews yet.

Be the first to review “M-CHEM 401 – Acid Resistant High Temperature Coating – Extended Cure”

Your email address will not be published. Required fields are marked *

Shopping cart

0
image/svg+xml

No products in the cart.

Continue Shopping